Cyber Insurance Application Scannermap an application to controls

CIS Controls v8 5.1: Establish and Maintain an Inventory of Accounts

Establish and Maintain an Inventory of Accounts is asked by 17 of the 48 carrier applications, through 27 questions. The evidence to have on file is Account inventory export from directory and key applications with required fields. This page maps the control to the questions that reach it; it never says whether an applicant will be offered cover.

CIS Controls v8 is read as each entry here is one CIS v8 Safeguard, our paraphrase of what it requires under the CIS title, read from the workbook CIS publishes and never the workbook verbatim; a mapping to a Safeguard does not establish that an applicant meets it. Every requirement here is our statement of its clause, cited to it, not the instrument verbatim.

Which carriers ask this control?

17 carrier applications reach this control: AIG, Arch Insurance, Argonaut Insurance Company, Aspen American Insurance Company, BOXX Insurance, The Cincinnati Insurance Company, CNA, Delta Insurance, Discovery Insure Ltd, Everest Insurance, Great American Insurance Group, Hiscox, Hiscox UK, Munich Re, Ocean Underwriting, QBE, USLI. A carrier named here is a source document, never a customer or an endorsement.

What evidence should be on file for 5.1?

Evidence guidance is our wording, not a statement of any standard and not binding on a carrier or an assessor.

Common gaps an assessor names

The one or two items a carrier would actually ask for

The application questions that reach 5.1 (27)

Application question A policy that requires strong passwords that should be updated on a regular basis?
Application question Password/passcode protected Encryption Traditional or next generation firewalls enabled/turned on Traditional or next generation antivirus products on all endpoints Endpoint Detection and Response (EDR) 24/7/365 on all devices If yes to EDR, Who is your provider?
Great American Insurance Group question 9 priority underwriting question
Application question Do these users require additional credentials to access?
Application question What is the minimum length for passwords?
Application question Do you enforce a strong/complex password policy of at least 8-20 characters?
Application question Does the Applicant enforce password changes every 8-12 weeks?
Application question Are unique backup credentials stored separately from other user credentials?
Munich Re question 50 priority underwriting question
Application question Do you have a formal password policy that explains good password hygiene, such as not using obvious or repeated passwords, for all systems providing access to personal or confidential information?
Application question Remote access to the corporate resources generally only requires a valid username and password (single-factor authentication).
Application question There's a password manager provided to all employees
Application question There's a policy in force against password reuse (uses unique passwords for apps in the environment)
Application question Are documented procedures in place for user and password management and are they monitored for compliance? Do you have a process for managing user accounts including promptly deleting or modifying access upon a change of responsibilities or termination?
Application question Are all users issued unique IDs and passwords when connecting to or accessing the internal network and do passwords require periodic changes, minimum length and mixed case, letters, numbers and special characters?
Application question Do you enforce a "clear screen" policy that includes clearing computer screens and requiring user logon and password authentication to re-access the device after a period of inactivity?
Application question Have you implemented a password policy enforcing the use of long and complex passwords across your organisation?
Application question Do you have procedures in place to restrict or remove login credentials of employees immediately following an employee's departure from your organization?
Application question Do you change any default administrative passwords to an alternative that is difficult to guess?
Application question Do you enforce password complexity requirements with a minimum password length of 12 characters?
Application question Do you use credentials unique to backups that are stored separately from other user credentials?
BOXX Insurance question 46 priority underwriting question
Application question Are all users issued unique passwords?
Application question Are all users' passwords encrypted?
Application question How often are passwords required to be changed?
Application question Does the Applicant have a policy requiring strong passwords?
Application question Does the applicant utilize the following controls: a. Anti-virus/Malware protection on all internet accessible devices; b. Firewalls or service that has configuration-designed and maintained to protect data; c. Intrusion detection software or service; d. Passwords that are complex and contain at least eight characters; e. Passwords that are changed every 90 days; f. Have an updated system that utilizes chip card technology; g. Default passwords changed on all third party hardware and software products?
USLI question 10 priority underwriting question
Application question Does the Applicant introduce password procedures to assist with the mitigation of a security breach, such as passwords to be changed on a regular basis e.g. Every 72 Days?
Application question Does the Applicant impose Strong Password Discipline e.g., Uppercase, Lowercase and Symbols?
Application question Do you require passwords which meet minimum standards of complexity (8+ characters, utilising: uppercase letters, lowercase letters, numeric digits, and non-alphanumeric characters) and that are amended from vendor-supplied or default passwords?

Controls reached by the same questions

11.2 (CIS Controls v8), 3.11 (CIS Controls v8), 5.2 (CIS Controls v8), 6.8 (CIS Controls v8), 8.2 (CIS Controls v8), A.5.15 (ISO 27001:2022), A.5.17 (ISO 27001:2022), A.5.19 (ISO 27001:2022), A.6.7 (ISO 27001:2022), A.7.1 (ISO 27001:2022), A.8.13 (ISO 27001:2022), A.8.15 (ISO 27001:2022), A.8.24 (ISO 27001:2022), A.8.5 (ISO 27001:2022).

This control on the island, all controls on the controls index, the framework on the CIS Controls v8 page, the carriers on sources. Map your own answers in the tool.